A) 1% neutralizes new systems and removes oils, dirt, sludge, fluxes, filings, etc.
B) 2% cleans central heating systems, even older ones whose condition does not allow the use of acids.
A very effective, acid-free cleaning and neutralising agent for water central heating, refrigeration and air-conditioning systems and cooling systems, etc. in industry and agriculture.
For use during normal system operation or with cleaning pumps.
For use in installations in single- and multi-family houses and in industrial installations.
- Penetrates, moves and dissolves rust, sludge, corrosion deposits and light mineral deposits.
- Neutralises corrosive agents in new systems: solders, fluxes, oils, sludge, etc.
- Ecological - non-acidic with near neutral pH, based on the newest generation of formulations.
- Does not require neutralisation after the cleaning process (it is recommended to use corrosion inhibitor after the cleaning process).
- Dissolved deposits do not cause blockage of pumps or valves even with normal system operation.
- It does not cause gassing of the cleaned systems and installations (emission of gases).
- Recommended e.g. for use with older central heating systems, whose condition does not allow the use of acids.
- For systems made of various materials, e.g. aluminium, galvanised, inox and standard plastics.
- Application time - cleaning with a pump a few hours, during operation of the central heating system up to about 2 weeks.
- The concentration of the preparation is not critical. It can be used in concentrations close to 1% - 2%.
TECHNICAL DATA
Form: Liquid
Odour: Slightly perceptible
Colour: Light yellow
Solubility in water: In all proportions pH: 6-7.5 pH
Relative density: 1.18
Concentration: Cleaning: 1L per 50 L water (2%), - Pre-cleaning/neutralisation: 1L /100 L water (1%).
Packaging: Ferdom: 1 litre (FD202), 5 litres (FD203) Ferpro; any quantity, minimum 10 kg (FP301)
DESCRIPTION OF APPLICATIONS
The effective acid-free agent is designed for rinsing, neutralizing and cleaning water installations, heating installations, etc;
A) New installations before commissioning to neutralise solders, fluxes, technical oils (from radiators and metal pipes) and other chemical impurities.
B) Existing water installations - to remove rust, corrosion deposits, light mineral deposits and loose substances such as sludge and contaminants that are by-products of corrosion with minimal risk of exposing leaks.
Contains inhibitors that protect all metals and materials commonly used in heating systems. Leaving the agent on for a longer period of time does not cause damage to the installation. Cleaning can be repeated if necessary.
CLEANING METHODS
DS-15 can be used both during the system operation and with a cleaning pump.
.
-Cleaning of a heating system (new or existing) during system operation consists in maintaining circulation for 7-14 days under normal operating conditions or for approx. 1 day maintaining a constant temperature of approx. 60-70°C. Using DS-15 does not require disconnection of the boiler or radiators, it is advisable to use the boiler to heat up the cleaning bath. When there is no possibility to heat up the heating installation, e.g. in summer season, or another installation is being cleaned, e.g. air-conditioning - the preparation is effective also at ambient temperature of approx. 20°C. In this case it is advisable to leave it in the installation longer - up to 4 weeks.
.
Cleaning of water installations by using the cleaning pop-up. It is advisable to heat up the cleaning bath to approx. 50 °C. Cleaning period up to about 6 hours. Use of Ferdom magnetic filter FM1 (FD001) is recommended.
GENERAL RECOMMENDATIONS FOR LARGE INSTALLATIONS
Cleaning without a cleaning pump while the system is running.
Recommended concentration of the preparation 1% to 2% (1 to 2 litres/dm3 per 100 litres/dm3 of water) depending on the degree of contamination of the installation.
1) Feed the preparation directly into the system. Concentrations are not critical.
2) For best results, drain and flush with tap water before cleaning.
3) Prepare the installation for cleaning. Open all valves in the system to full flow, including thermostatic controls and automatic control valves. They must be open so that no part of the circuit is disconnected during cleaning.
4) The introduction of the preparation should take place after complete / partial draining of the system, in an open system through an expansion vessel or through a place in the system chosen by the installation team.
5) The cleaning process is faster and more effective at higher temperatures. The boiler and circulating pump should be connected to the central heating system and operate within the normal temperature range.
6) At 60-70oC the cleaning time can be reduced to approx. 24-48 hours.
7) In the event that the system/boiler cannot be switched on during the
7) If the system/boiler cannot be switched on during the cleaning process, e.g. in summer, the DS-15 can remain in the system for approx. 4 weeks. Turn on the circulation pump from time to time. When the system is very dirty, it is advisable to fit a Ferdom FM1 magnetic filter.
8) The cleaning process should be monitored and continue for as long as necessary (and possibly be repeated) in accordance with the results of the cleaning process monitoring.
9) The next step is to drain the system completely and rinse it with cold water. Carefully flush the system until the water is clear. This requires at least three water changes. To protect the system for the future, it is recommended to use a corrosion inhibitor.
CLEANING OF OTHER WATER INSTALLATIONS
The cleaning method for other installations depends on their type. It is advisable to heat up the cleaning bath for faster action of the product and to use a forced closed circuit. Most of the recommendations for central heating installations can be applied for cleaning other systems.
There are currently no product reviews.
Write ReviewThe owner of the online store does not guarantee that the published opinions come from consumers who have used or purchased a given product.
FD407 FERDOM (3 x FD405) FD406 Dispenser Refills. Anti-Corrosive and Anti-Sludge. For 60m3.
Without Tax: 10.39 EUR
With Tax: 12.78 EURDS-30 "FERDOM" An effective, safe descaler for water installations. Packaging 30 kg.
Without Tax: 415.47 EUR
With Tax: 511.03 EURFIRE GO "FERDOM" 400 mL x 3 pcs. A spray for cleaning combustion chambers of domestic gas boilers.
Without Tax: 21.73 EUR
With Tax: 26.72 EURFD246 WATERCLEAN 3pcs Pre-Filter 3/4"-1", 4m3/h, 40-60μm Inox Mesh 90cm2, Scraper. Self-Cleaning.
Without Tax: 118.08 EUR
With Tax: 145.24 EURFD406 DISPENSER-WATER SOFTENER x 3 units - Anti-Sediment and Anti-Corrosion. For Domestic Systems.
Without Tax: 103.73 EUR
With Tax: 127.58 EURFD169 3x1 kg Preparation/Balls Condensate Neutraliser for Condensing Boilers FERDOM
Without Tax: 55.55 EUR
With Tax: 68.32 EUR